Roentgen X-Ray tube (P-8696)
Consists of cathode ray tube. Cathode rays from cathode are allowed to fall on a high density, high atomic weight material say, Tungsten. Under reflection the cathode rays are converted into x-rays. Works on 10 cm spark gap induction coil. The x-rays produced are soft x-ray but must be prohibited for over exposure. Comprises a glass sphere with concave disc electrode generating cathode rays and focus on a tungsten target placed at 45° angle, at the inner end of arm exactly opposite. Dia of Tube : 80mm, 90mm, 110mm
|
|
|
|
Click to Enlarge
|
Spectrum Tubes (P-8706)
These tubes are straight and available in two sizes 20cm & 26cm in length. The electrodes are placed in either side of the tube and connected with fine capillary tube in between. Available with (a) Helium, (b) Neon, (c) Ar, (d) Hydrogen, (e) Oxygen, (f) Nitrogen, (g) Iodine Vapours, (h) Alcohol vapours, (i) Carbon dioxide (j) Carbon Monoxide (k) Chlorine (l) Deuterium (m) Krypton (n) Sulphur (o) Xenon (p) Bromine etc. filled. Suitable for the observation of the typical spectrum of the gas filled in side the tube.
|
|
|
|
Click to Enlarge
|
Spectrum tube on stand with power supply (P-8706/1)
|
|
|
|
Click to Enlarge
|
Spectrum tube on stand without power supply (P-8706/2)
|
|
|
|
Click to Enlarge
|
Magnetic Effect Deflection (P-8713)
Running cathode rays are visible to naked eye by glowing path on fluorescent screen. The deflection of the cathode rays under magnetic field may be demonstrated easily by moving magnet across the same.
|
|
|
|
Click to Enlarge
|
Rectilinear Propagation (P-8715)
V shaped tube. To show cathode rays are generated only vertical (lower electrode) irrespective of the anode points (any of two electrodes above).
|
|
|
|
Click to Enlarge
|
Heating Effect Wax Coating (P-8719)
When cathode rays are focused on wax coated on the outside of the upper round head of cathode ray tube, the wax melts quickly showing heat generated by cathode rays.
|
|
|
|
Click to Enlarge
|
Shadow Effect (Maltese Cross) (P-8721)
When the cross is placed in the path of the cathode rays, a sharp shadow is formed. Its sharpness is an indication that the rays are emitted from the cathode in a definite direction and not like from a luminous surface in all direction. It shows that the cathode rays travels in straight line.
|
|
|
|
Click to Enlarge
|
Vacuum Tubes on Stand (P-8723)
Vacuum tubes are mounted on a stand with different pressures in them. Gases are added to intensify the luminescence. Tubes are 30 cm long. Works on induction coil or 10KV power supply.
|
|
|
|
Click to Enlarge
|
Geissler's Tubes on Stand (P-8725)
Six vacuum tubes of various shapes and designs, and different degrees of vacuum inside showing different discharge phenomenon illuminations and patterns etc. Tubes are mounted in a glass/wooden case with rotary switch for connection of any of the tubes.
|
|
|
|
Click to Enlarge
|
Geissler's Tubes, Set of Six (P-8726)
|
|
|
|
Click to Enlarge
|
High Tension Power Supply (P-8729)
Suitable for spectrum tubes, with ON/OFF and selector switch. Output 5KV, 2-3 milliamps. Operating on 220V AC, 50 Hz, Housing in sheet metal case.
|
|
|
|